Product Categories

73 Organic Acids LC-MS/MS analysis kit

73 Organic Acids LC-MS/MS analysis kit
CE-IVD certified and suitable for any kind of LC-MS/MS instrument

 

The Zivak 73 Organic Acids LC-MS/MS analysis kit can be used in combination with the Zivak-Multitasker as well as manually. Analysis run time for the manual version is 20 minutes. Due to the efficient and quite smart procedure of the Zivak-Multitasker, the automated version guarantees to receive quantitative results in just 20 minutes per test, including sample preparation-, sample injection- and analysis run time. Additionally, high accuracy is being rectified through external quality tests.

Consumables for this kit please click here

Quantitative LC-MS/MS analysis kit for Organic Acids in human urine samples.

Organic acid disorders (organic acidemia) are a group of inherited metabolic conditions. Most of the organic acidemias caused by defective autosomal genes for various enzymes for amino acid metabolism. Neurological and physiological harms are caused by this impaired ability to synthesize a key enzyme required to break down a specific amino acid, or a group of amino acids, resulting in acidemia and toxicity to specific organs systems. Most are inherited as autosomal recessive diseases. Organic acid related disorders may affect many metabolic pathways including amino acid, lipid metabolism, fatty acid oxidation and the Krebs cycle.

Organic acidemias are usually diagnosed in infancy, characterized by urinary excretion of abnormal amounts or types of organic acids. The diagnosis is usually made by detecting an abnormal pattern of organic acids in a urine sample. In some conditions, the urine is always abnormal, in the others the characteristic substances are only present intermittently. Many of the organic acidemias are detectable by newborn screening with Tandem Mass spectrometry. These disorders vary in their prognosis, from manageable to fatal, and usually affect more than one organ system, especially the central nervous system.

Quantitative analysis of the organic acids in urine samples have clinical importance for determining organic acidemias and monitoring the organic acid concentrations in human urine. ZIVAK Quantitative Organic Acid LC-MS/MS kit was developed for quantitative detection of the 73 major organic acids in human urine samples. LC-MS/MS is a influential device for the study of metabolic disorders and LC-MS/MS analysis gives results in 20 minutes with minimal sample preparation. Main methods and procedures that we selected are based on EN ISO 13485 and 98/79/EC.

 

73 Organic Acids LC-MS/MS analysis kit 0 73 Organic Acids LC-MS/MS analysis kit 1
73 Organic Acids LC-MS/MS analysis kit 0 73 Organic Acids LC-MS/MS analysis kit 1
  • This analysis kit can be shipped at room temperature. 
  • After arrival, reagent 1,2,3 , calibrators and controls should be stored at 2-8 °C.  
  • All other components of the kit should be stored at room temperature.
  • All components are guaranteed until expiry date when stored at recommended temperatures and used as described in these instructions.
73 Organic Acids LC-MS/MS analysis kit 0 73 Organic Acids LC-MS/MS analysis kit 1
 
73 Organic Acids LC-MS/MS analysis kit 0 73 Organic Acids LC-MS/MS analysis kit 1
File Name Type Size Download
User Manual 1.81 MB

Zivak General Catalog

Download Zivak General Catalog PDF