The Zivak 47 Amino Acids LC-MS/MS analysis kit can be used in combination with the Zivak-Multitasker as well as manually. Analysis run time for the manual version is 20 minutes. Due to the efficient and quite smart procedure of the Zivak-Multitasker, the automated version guarantees to receive quantitative results in just 20 minutes per test, including sample preparation, sample injection and analysis run time. Additionally, high accuracy is being rectified through external quality tests.
Quantitative LC-MS/MS analysis kit for Amino Acids in biological fluids (Urine & Plasma & Serum Fluid).
Amino acids are the basic structural units of proteins. Quantitative analysis of amino acids in biological fluids is one of the most important parts of the clinical diagnosis of patients with inborn errors of amino acid metabolism or monitoring healthy people. Amino acid analysis in urine is important for diagnosis of disorders which are related with renal amino acid transport. Quantitative analysis of amino acids in plasma is preferred over urine for the diagnosis of aminoacidopathies which cause to accumulation or the deficiency of amino acids in biological fluids.
Quantitative analysis of amino acids in biological fluids also has clinical importance for determining some neurological and endocrinal disorders. LC-MS/MS is an influential device for the study of disorders related with amino acids. LC-MS/MS analysis gives results for 47 free amino acids in 20 minutes.
Zivak Quantitative Free Amino Acids LC-MS/MS Analysis Kit was developed for quantitative detection of free amino acids in human serum, plasma, urine and cerebrospinal fluid LC-MS/MS is an influential device for the study of metabolic disorders and LC-MS/MS analysis gives results in 20 minutes with minimal sample preparation. Main methods and procedures that have been selected are based on EN ISO 13485 and 98/79/EC.
LC-MS/MS parameters : contact for more details
Storage & Stability
- This analysis kit can be shipped at room temperature.
- After arrival, standards and controls should be stored at 2-8 °C.
- Reagent 1, 2, 3, 4 should be stored at 2-8 °C.
- All other components of the kit should be stored at between room temperature.
- Reagent 2, 3 and 4 are volatile, please make sure that the lids of reagent bottles are closed tightly after use.
- All components are guaranteed until expiry date when stored at recommended temperatures and used as described in these instructions.
Preparation of Calibrators & Controls: contact for more details
Order No. |
Volume |
Component |
ZV-3002-02R1-10 |
1 x 30 ml |
Reagent 1, Contains deuterated internal standards |
ZV-3002-02R2-10 |
1 x 50 ml |
Reagent 2, Contains base |
ZV-3002-02R3-10 |
1x 50 ml |
Reagent 3, Contains derivatization reagent |
ZV-3002-02R4-10 |
1 x 50 ml |
Reagent 4, Contains organic modifier |
ZV-3002-02RH-10 |
1 x 30 ml |
Reagent H, Protective Reagent for HCYS |
ZV-3002-02MA-10 |
1 x 1 L |
Mobile Phase A, Contains organic solvent |
ZV-3002-02MB-10 |
1 x 1 L |
Mobile Phase B, Contains organic solvent |
ZV-3002-02WB-10 |
1 x 1 L |
Washing solution, Contains organic solvent |
ZV-3002-KK-10 |
1x1 pc |
User Guide |
Order No. |
Volume |
Component |
ZV-3002-02S1-10 |
1 x 3 ml |
Lyophilized Plasma Calibrator Level-1 |
ZV-3002-02S2-10 |
1 x 3 ml |
Lyophilized Plasma Calibrator Level-2 |
ZV-3002-02S3-10 |
1 x 3 ml |
Lyophilized Plasma Calibrator Level-3 |
ZV-3002-02K1-10 |
1 x 3 ml |
Lyophilized Plasma Control Level 1 |
ZV-3002-02K2-10 |
1 x 3 ml |
Lyophilized Plasma Control Level 2 |
ZV-3002-02K3-10 |
1 x 3 ml |
Lyophilized Plasma Control Level 3 |
ZV-3002-SGS1-10 |
1 x 3 ml |
Lyophilized Plasma Extra Calibrator Level 1 |
ZV-3002-SGS2-10 |
1 x 3 ml |
Lyophilized Plasma Extra Calibrator Level 2 |
ZV-3002-SGK1-10 |
1 x 3 ml |
Lyophilized Plasma Extra Control Level 1 |
ZS-2ML-8-1001 |
2x100pcs |
2 ml glass autosampler vial for automated Sample Preparation |
ZS-9004-0100-00 |
2x100pcs |
2 ml glass autosampler vial caps pre-slit for automated Sample Preparation |
ZV-3002-02C1-10 |
1 x 1 pcs |
Zivak Amino Acid Biological Fluids LC-MS/MS Analytical Column |
© 2024 Zivak. All Rights Reserved.